IMPAX 6.5.1 Client Knowledge Base: Extended > Reading studies > Modifying series display
While the screen format setting defines how many series are displayed at once on one monitor, the series view mode defines which series are displayed on which monitor. Series view mode applies only when the same studies are displayed on two or more monitors.
To set the default series view mode for each modality (and, optionally, body part), use the Screen Layout tab of the Customize dialog. To change series view mode for the current study, set the Series View Mode tool to one of two states:
| Button | Name | Effect |
|---|---|---|
| Same series | Displays the same series across all monitors displaying the same studies. | |
| Different series | Displays different series on each monitor displaying the same studies. |
To change the series view mode from same series
If necessary, set the study view mode to Span
Two Monitors
or to Span All Monitors.
If the study view mode is set to Span One Screen
,
you cannot change the series view mode.
From the Image area top toolbar, click Series
View Mode.
The button changes to
.
Each monitor displaying the same studies now displays different series
of that study.
To return to viewing the same series on each monitor, click Series
View Mode.
The button changes back to
and
each
monitor displaying the same study now also displays the same series.
See also - Administration
Defining screen layout defaults
Defining which monitor displays the Image area
See also - Clinical
Applying a system screen layout