IMPAX 6.5.1 Application Server Knowledge Base > Managing RIS connections and report sources
The Connectivity Manager is a middleware component in the integration between HIS, RIS, modalities, and PACS systems, linking patient and study data with images. To display report information available from a queryable RIS in the Text area of IMPAX, connect to the Connectivity Manager. For additional information on the IMPAX Client Text area, refer to "Text area overview" (topic number 8124) in the IMPAX 6.5.1 Client Knowledge Base: Extended.
To connect IMPAX to a local IMPAX RIS, refer to Connecting the Application Server to a local IMPAX RIS.
To connect the Application Server to a queryable RIS through the Connectivity Manager
Switch to the Web Services tab.
In the Report Info Sources area, click Add.
In the Edit Report Source dialog, in the Report Source Provider field, type the Default Assigning Authority name identified when the Connectivity Manager custom RIS mappings were configured.
A maximum of 64 characters can be entered in this field.
From the RIS Type list, select Connectivity Manager Queryable RIS.
In the URL field, type the following:
http://Connectivity_Manager_Server/CMReportServerInterface/CMReportServer.asmx
To close the Edit Report Source dialog, click OK.
To close the Business Services Configuration Tool, click OK.
See also
Connecting the Application Server to a remote IMPAX RIS using Connectivity Manager
Topic number: 11346 Applies to: IMPAX 6.5.1 Application Server Knowledge Base |