IMPAX 6.5.1 Client Knowledge Base: Extended > Administering IMPAX > Configuring dictation > Configuring the IMPAX Reporting solution > Configuring IMPAX Reporting: Workflow > Configuring the IMPAX RIS Client

IMPAX RIS Parameters


When operating an IMPAX Reporting system, several parameters on the IMPAX RIS make the integrated system perform optimally for your radiologists and their workflows. For complete details of the IMPAX RIS parameters, including valid values, refer to the RIS-PACS -Reporting with IMPAX Reporting Integration Guide.

Parameters cached on the IMPAX Client require a Client restart after modification and parameters cached on the Application Server require an IIS reset after modification.

Note:

Note:

Nuance SpeechMagic users (radiologists using speech recognition) must be defined in the IMPAX RIS (QManager) and in the Nuance SpeechMagic Administration tool. For more details, refer to the RIS-PACS -Reporting with IMPAX Reporting Integration Guide.

IMPAX RIS parameterDescriptionCached on IMPAX ClientCached on Application Server

ALWAYS_ADD_STATUS_LINE

Defines when the report status line is added to the report.

Yes

BLOB.BUFFERMAXSIZE

Sets the maximum buffer size when retrieving or saving blobs from and to the database.

Yes

DICT_DEFAULT.PRIORITY

Sets the default dictation priority for transcriptions and corrections.

Yes

DOC_DISTRIBUTION.PRINTERGROUP

Defines the name of the printer group to which the current workstation belongs.

Yes

DOC_DISTRIBUTION.VERSIONING

Defines whether report versions are distributed.

Yes

EXAMPRIORITY.MAPPINGRQEXTODICTPRIORITY

Maps the rqex to dictation priority.

Yes

HL7PACS.ACCESSIONNR

Defines which accession number IMPAX RIS sends to Connectivity Manager.

Yes

HL7PACS.PATIENTID

Defines which patient identifier IMPAX RIS sends to Connectivity Manager and IMPAX.

Yes

LETTER.ADDENDUM

Enables the addendum workflow in the Report panel of the Text area.

Yes

LETTER.ADDENDUM_INSERT

Determines where an addendum is inserted in the validated report.

Yes

LETTER.AUTHOR_VALIDATION

Determines who can validate reports.

Yes

LETTER.AUTOPRELIMINARY

Marks new reports as preliminary automatically.

Yes

LETTER.PRELIMINARY

Adds a PRELIMINARY watermark on the report if the report is marked accordingly.

MS Word must be installed on the Client for the watermark to be displayed.

Yes

LETTER.RTR_FOR_STATUS

Defines exam statuses for filling in the MediWeb results table.

Yes

LETTER.TEXT_ADDENDUM_STRING

Defines the addendum formatting, such as the user name, date, and time.

Yes

LETTER.TEXT_ADDENDUMVALSTATUS

Enables and defines the addendum status line to display in the addendum report.

Yes

LETTER.TEXT_DOCVAL_INITIALS

Defines the label that appears before the physician name in the report.

Yes

LETTER.TEXT_DOCVAL_SIGNATURE

Defines how the name of the radiologist validating the report is displayed when printed.

Yes

LETTER.TEXT_REPORTVALSTATUS

Defines the report status line to display in the report.

Yes

LETTER.USEWATERMARKS

Adds watermarks on all reports.

Yes

LETTER.VERSIONING

Enables report versioning.

Yes

LETTER.VERSION_FOR_STATUS

Creates report versions based on status on the Application Server. Any valid report statuses for which a version can be created: NL,PV,VL,IL,DL,AV. Typical values are: NL,VL,AV or VL,AV.

Yes

PATIENT.ADDNAMEPARTNER

Defines how a married woman's name is displayed.

Yes

PATIENT.ACTIVATEMPI

Activates the master patient index (MPI) system.

Yes

PROTOCOL.SAMEAUTHORANDDONEBY

Determines whether the performing physician in the request can be modified when the author in the Reporting dialog is changed.

Yes

QBRIDGE.INSTALLED

Defines which printing component is installed, if any.

Yes

RECOGNITION.ACOUST_ADAPT

Enables or disables acoustic adaptation.

Yes

RECOGNITION.CONTEXT_ADAPT

Determines whether speech adaptation is done by the IMPAX Client or the Agfa Speech Adaptation service.

Yes

RECOGNITION.USE_SERVER_MODE

Enables or disables context adaptation.

Yes

REPORTING.PROXY_SIGNING

Disables the proxy sign-off. The proxy sign-off worklist contains the reports from all the colleagues on whose behalf the selected radiologist can sign off reports.Yes

SPEECH.DICT_INCLALLEXAMS

Determines which exams are selected in the Reporting options dialog.

Yes

SPEECH.INSTALLED

Enables or disables SpeechMagic and activates the Dictate button in the Text and Image areas.

Yes

SPEECH.INTERACTIVE

Sets the warning threshold for low audio quality events.

Yes

SPEECH.INTERACTIVE_AUDIOQUALITY

Sets the warning threshold for low audio quality events.

Yes

SPEECH.OVERLOADUSER

Determines if settings for acoustic feedback and winding speed are determined by the relevant IMPAX RIS parameters or by the physician setup.

Speech settings are only displayed in the IMPAX Reporting Service window if this parameter is set to 0. If set to 1, the speech settings for the physician are not shown but are still taken into account.

Yes

SPEECH.PLAYBEEP

Plays a sound every time the recording mode is started or stopped. We recommend using a click or beep sound.

Yes

SPEECHNOTE.MONKEYCHATTER

Determines if acoustic feedback is played when fast forwarding or rewinding through a dictation.

Yes

SPEECHNOTE.STORAGEPATHFORIAFILES

Defines where dictation and transcription sound files are stored for online dictations from IMPAX.

Yes

SPEECHNOTE.STORAGEPATHFORSOUNDFILES

Defines where dictation and transcription sound files are stored for digital offline dictations from IMPAX.

Yes

SPEECHNOTE.WINDINGSPEED

Determines the winding speed when fast forwarding or rewinding through a dictation.

Yes

TEXTAREA.ADDENDUM_EXTENDED

Enables the speech recognition reporting addendum workflow in the Report panel of the Text area.

Yes

TEXTAREA.DISABLE_DIGDIC

Enables the digital dictation workflow in the Report panel of the Text area.

Yes

TEXTAREA.DISABLE_OFFLINE

Enables the offline dictation workflow in the Report panel of the Text area.

Yes

TEXTAREA.DISABLE_ONLINE

Enables the online dictation workflow in the Report panel of the Text area.

Yes

TEXTAREA.DISABLE_SUBMIT_FOR_CORR

Enables the Submit for correction button in the Text area.

Yes

TEXTAREA.DISABLE_SUSPEND

Enables the Suspend button in the Report panel of the Text area.

Yes

TEXTAREA.ENABLE_DELETE

Enables the Delete button on the Report panel of the Text area for selected users.

Yes

TEXTAREA.ENABLE_UNVALIDATE

Enables the Unvalidate report button in the Report panel of the Text area.

Yes

TEXTAREA.EOL_PRINT_TO_DEFAULT

Activates printing through a default printer.

Yes

TEXTAREA.EXTENDED_SIGNOFF_AND_EDIT

Extends report editing beyond the radiologist who created the report and report sign off beyond the radiologist assigned to sign off reports or proxy groups.

Yes

TEXTAREA.FETCHDICTATION _BEHAVIOR

Fetches dictations. Applies to all types of dictations.

Yes

TEXTAREA.LIMITPRIORSTUDIESORADNM

Obsolete. This parameter has been replaced by the TEXTAREA.LIMITPRIORSTUDIESOQL parameter.

Yes

TEXTAREA.LIMITPRIORSTUDIESOQL

When enabled, filters studies based on IMPAX RIS criteria. It is mainly used to filter out studies which are only known to the IMPAX RIS.

Yes

TEXTAREA.MPI_PATIENT_ID_MASK

Specifies the mask that the RIS web service uses when sending out patient IDs and when being queried by patient ID.

Yes

TEXTAREA.QDOC_SHORTCUTS**

Adds buttons to the Order panel in the Text area that are shortcuts to QDoc:

Yes

TEXTAREA.QPLANNER_SHORTCUTS**

Adds buttons to the Order panel in the Text area that are shortcuts to QPlanner:

Yes

TEXTAREA.QPORDER_SHORTCUTS**

Adds buttons to the Order panel in the Text area that are shortcuts to QpOrder:

Yes

TEXTAREA.SIGNOFFLOOKBACKPERIOD

Sets how far back reports are retrieved for sign off in the Report panel of the Text area.

Yes

TEXTAREA.STUDYREASON_CATEGORY

Defines the category used to display the reason for study in the Text area.

Yes

TEXTAREA.TECHNOTE_CATEGORY

Defines the comment category used for the technologist comments displayed in the Text area.

Yes

TEXTAREA.TWO_VALIDATION_BUTTONS

Controls validation and edit rights within IMPAX Reporting.

Yes

VERSIONING.COMPRESSION

Enables compression for report versions.

Yes

WORDPROCESSING.ADD_PAT_DOC_ADDRESSEE

Adds the patient's physician automatically as the recipient of the report.

Yes

WORDPROCESSING.ALLOWCHANGEEXAMSELECTION

Determines whether the exam selection can be changed.

Yes

WORDPROCESSING.CMBAUTHORSMODE

Specifies whether to use only the name, the code, department or a combination in the author list box of the Reporting options dialog.

Yes

WORDPROCESSING.COMPRESSION

Sets whether reports are compressed before being stored in the database.

Yes

WORDPROCESSING.DOCPATH

Defines the temporary report and versions path.

Yes

WORDPROCESSING.FULLVALIDATION

Enables the full validation of reports.

Yes

WORDPROCESSING.PROTECTDOCUMENT

Enables you to protect sections of the report templates from editing by users.

Yes

WORDPROCESSING.STORAGEFORMAT

Sets the storage format of reports (RTF or DOC).

Yes

WORDPROCESSING.TEMPLATEPATH

Defines the location of the report templates used by Microsoft Word.

Yes

To enable any of the shortcut buttons to the IMPAX RIS in the IMPAX Text area, the HKEY_LOCAL_MACHINE\SOFTWARE|Quadrat\UsePVMitraCM must be set to yes and the HKEY_LOCAL_MACHINE\SOFTWARE|Quadrat\QDLink\SingleSignOnDB must be set to the RIS database name that is used for single sign-on.